Description
“Customers have universally stressed the need for more durable industrial chargers. We built the IC650 within a fully sealed die cast aluminum enclosure to withstand the high vibration and exposure to dust and moisture that is typical of on-board environments,” said Evan Sanders, Vice President, Global Sales at Delta-Q.
“Delta-Q also added features that customers have requested to support fleet management initiatives and simplify field service, like the charger’s ability to use a USB memory stick to download the charger’s data log or update its software,” added Sanders.
Delta-Q has commenced volume production shipments and evaluation samples are readily available for OEMs to order. The IC650 OEM Installation and Design Guide has been released to provide instructions for selecting the right charger model and designing it into a vehicle or machine application.
| DC Output | 24 VDC | 36 VDC | 48 VDC |
|---|---|---|---|
| Enerdrive Part Number | 940-0004 | 940-0005 | 940-0006 |
| Nominal DC Output Voltage | 24V | 36V | 48V |
| Maximum DC Output Voltage | 36V | 54V | 72V |
| Maximum DC Output Current | 27.1A | 18.1A | 13.5A |
| Maximum DC Output Power | 650W | ||
| Deep Discharge Recovery – (minimum voltage) | 1.2V | 1.8V | 2.4V |
| Maximum Interlock Current | 1A | ||
| Battery Type | Lead acid (Wet / AGM / GEL), Lithium Ion | ||
| Reverse Polarity | Electronic protection with auto-reset | ||
| Short Circuit | Electronic current limit | ||
| AC Input | ||
|---|---|---|
| AC Input Voltage Range | 85 – 270 Vac | |
| Normal AC Input Voltage | 100 – 240 Vac | |
| Normal AC Input Frequency | 50 / 60 Hz | |
| Maximum AC Input Current | 7.5 A | |
| Nominal AC Input Current | 7.3 A @ 100 Vac – 6 A @ 120 Vac – 3.1 A @ 230 Vac – 2.9 A @ 240 Vac | |
| Nominal AC Power Factor | > 0.99 @ 120 Vac – > 0.98 @ 230 Vac | |
| Regulatory | |
|---|---|
| Efficiency |
93.5% peak, California Energy Commission compliant
|
| Safety |
Approval pending to UL1564, CSA 107.2, EN 60335-2-29
|
| Emissions |
FCC Part 15 / ICES 003 Class A, EN55011
|
| Immunity |
EN61000-3-2, EN61000-3-3, EN 61000-4-2/-3/-4/-5/-6/-11
|
| Mechanical | |
|---|---|
| Dimensions | 25.2 x 18.6 x 8 cm |
| Weight | < 3 Kg |
| AC Input connector | IEC320 / C14 (requires country-specific cord) |
| DC Output connector | M6 threaded fasteners for ring terminals |
| Service port | Sealed (IP66) USB 2.0 Host Port (Type A) with dust cover |
| Mounting holes | Allows for safe installation on shelf, wall or bulkhead |
| Cooling | Normal operation in any orientation with passive cooling only |
| Environmental | |
|---|---|
| Enclosure | IP66 (NEMA4) |
| Operating Temperature | -40oC – 65oC (de-rated at >40oC) |
| Storage Temperature | -40oC – 85oC |