Lithium Battery Installation Kits

To Suit Enerdrive Lithium Power Pack Batteries, available in 100Ah, 200Ah, 300Ah, 400Ah & 500Ah capacities.

Enerdrive has a complete lithium battery and installation solution to suit nearly every application.

Description

Enerdrive lithium battery power pack

Enerdrive Lithium Ion Installation Kit Mounted on Zinc Power Coated Plate.

Enerdrive have designed and created a COMPLETE Battery & Installation System so your Li-ion battery bank is fully protected and designed to give maximum performance and longevity.

High Cell Voltage Situations – 4 Contacts are supplied to use for  External Relay Control of Charging Sources.

  • 2 x Normally Open Contacts (1 amp Max) each – used to operate Relays connected to  Chargers, Solar or a DC/AC relay connected to Combi Units.
  • 1 x Normally Closed Contact (5 amp Max) – used to operate Relays connected to Chargers, Solar or a DC/AC relay connected to Combi Units.
  • 1 x Normally Closed Contact (10 amp Max) – used to operate Field wire of Alternator, Requirements of Alternator must be assessed to see if this is suitable as will not suit all applications

Advanced BMS Relay Driver

Low State of charge (SOC%) Relay Cut Out.

The system is designed to disconnect the battery if it has been drained to a pre-set capacity. When the monitor registers the low SOC% set point, it will disengage the Blue Sea Latching Relay to prevent further discharge and/or damage to the battery.

To charge the battery from this state, turn off all loads, manually engage the latching relay by pressing the Yellow button on top of the relay and turn on the charging source/s. If the ePRO monitor does not register a minimum 1% increase in the SOC% within 6 minutes, the relay will disengage again to protect the battery. If this happens, re-engage the relay and continue charging. When the monitor registers 1% SOC% increase above the pre-set low capacity point, the system will stay active. Keep the charging source/s running to fully charge the battery. Once the capacity reaches 30% SOC, you may reactivate the loads.

System Program Selection Switch

The Enerdrive Advanced BMS Relay Driver has 2 pre-programed settings. Output 1-4 Disabled; is programmed if you do not wish to use the Output contacts. If the battery SOC% is Low or Cell Voltage is high, the Blue Sea relay will disengage, turning off the whole system to protect the Battery.

Output 1 – 4 Enabled; is programmed if you wish to utilise the Output contacts. Using the program allows you to have the charging sources run through external relays allowing the BMS to isolate the charging source in the event of a cell voltage being to high without turning the whole electrical system Off. In the event of low SOC% the Blue Sea relay will still be disengaged to protect the battery.

Lithium Battery System Wiring Diagrams

Click on the thumbnail below to download the Wiring Diagram PDF file.

Lithium Battery with ePro Combi Battery Charger / Inverter

ePRO Combi Inverter Charger Lithium System Diagram

Lithium Battery with ePro Combi Battery Charger / Inverter

ePRO Combi Hybrid Lithium System Diagram

Lithium Battery with Morningstar Tristar MPPT

ePOWER Battery Charger – Morningstar TriStar Lithium System Diagram

Lithium Battery with ePower Battery Charger

ePOWER Battery Charger Lithium System Diagram

You will require the Adobe® Reader® software installed on your computer to view these files. You can download the reader by clicking on the link below.

Adobe® Reader® software is the free global standard for reliably viewing, printing, and commenting on PDF documents.

Get Adobe Reader